<LOGO>
FM Transmitter Measurement Report
Created: 2023-06-03 13-53-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 79 dBuV RIRE &
Pilot RDS Phase Difference
7.0 kHz 3.6 kHz 50 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
9 kHz 65 kHz 17226 0,0290
Modulation Power
Limit Measuring Tolerance
8,0 dBr 0,0 dBr
MIN AVE MAX % above 8,0 dBr
4,6 dBr 5,14 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 13:53, 3.06.2023
RT
"RIRE & C "
AF EON
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (79 dBuV) Max at: 65 kHz MIN: 9 kHz % above 75 kHz: 0,0290 Acquired: 2023/06/03 13:52:44 Total samples: 17226 Equivalent time: 0:14:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,6 dBr MIN: 4,6 dBr AVE: 5,14 dBr % above 8,0 dBr: 0,0 Last value: 5,1 dBr (2023/06/03 13:52:37) Station: 101.50 MHz, signal: 5/5 (79 dBuV) 13:40 13:42 13:44 13:46 13:48 13:50 13:52 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality